# Sync model
2
3
Beacon is offline-first: every change is written to the local store and enqueued, and the queue is
4
drained whenever there is a connection. A technician can work a full day in a basement and lose
5
nothing.
6
7
The queue is ordered per job and unordered between jobs, so a stuck photo upload on one job cannot
8
hold up a signature on another. Each entry carries a client-generated id, which is what makes the
9
server side idempotent.
10
11
Conflicts happen when the same job was edited on the server while the device was offline. The device
12
keeps both versions and asks. That dialog is the part of the app people complain about most, and the
13